Technical specifificaons
The product requires export license. Pictures are referential. Specifications are subject to change without notice. Doc.:M43332BE
Performance Characteriscs Unit LRX-25A Note
Laser safety class - 1 Eye safe
Wavelength μm 1.5
Measurement range m 50 - 32 000
Measurement range
Standard target
m 10 000
Target size 2.3 x 2.3 m, visibility 15 km, target re-
flflecvity 30%, detecon probability >90%
Exncon rao dB 41.0
Large target @ 500 m, visibility 23 km, target reflflec-
vity 85%
Measurement me s 0.7 / 1.7 Typical / Max. performance measurement two
mes in ten seconds due to eye-safety
Connuous measurement rates Hz
1, 4, 10, 20,
100, 200
With reduced measurement ranges
Precision m 0.5 - 1.5 Depending on the distance and target reflflecvity
Beam divergence mrad 0.35
False detecon rate % < 1
Target discriminaon m < 30 Depending on the received signal level
Range gang resoluon m 1
Operang temperature °C -32 - +60
Storage temperature °C -40 - +71
Mechanical characteriscs Unit LRX-25A Note
Size (L/W/H) mm 88 x 53 x 37
Weight g 136
Alignment retenon mrad 0.2 Within operang temperature range
Alignment pointer nm 635 Laser Class 1
IP Protecon - N/A
Electrical characteriscs Unit LRX-25A Note
Serial interface - RS422 Connector type: Molex 53261-1071
Supply voltage V 7 - 30
Start-up me ms < 50
Power consumpon
during measurement
W < 4
Power consumpon
in Stand-by mode
W < 0.2
Unit can be completely shut down by external sig
nal to further minimize power consumpon
This document describes mechanical, optical, electrical and software interface of the
following Noptel LRX family modules:
? LRX-20A
? LRX-25A
? LRX-42A
Figure 1. LRX-20A and LRX-25A
Figure 2. LRX-42ADocument number
OS43418IE
Document nam
1.2.1 Class 1 modules
The LRX is eye-safe in every measurement mode.
The system which uses Class 1 LRX module shall have labelling according IEC 60825-
1:2014 as follows:
Text borders and symbols are recommended to be black on a yellow background, but for
Class 1 this color combination need not be used.
The labels shall be durable, permanently affixed, legible, and clearly visible during
operation, maintenance or service, according to their purpose.
If the size or design of the product makes labelling impractical, the label shall be included
with the user information or on the package.
Direct printing or engraving of equivalent labels on the laser product or panels is
acceptable.
Table 4: Molex connector pinout
pin # IN/OUT Description
1 IN RS-422 RX+ (or UART TXD) *1
2 IN RS-422 RX- (or RS-232 RX or UART RXD) *1
3 GND RS-422 GND
4 OUT RS-422 TX+ *1
5 OUT RS-422 TX- (or RS-232 TX) *1
6 GND Case/Supply ground *2
7 & 8 IN Supply voltage input (6.5 - 30V). Reverse voltage protected. See Table 5
for power consumption.
9 GND Case/Supply ground *2
10 IN Shutdown when pulled down <0.5V, Power On when > 1.1V(internal 100
kΩ pull up)
*1 The default interface is RS-422. Serial interface option must be defined during ordering.
*2 Isolation of the case from the electrical ground is possible. Isolation option must be defined in the order!
Table 5: Typical power consumption of the LRX-20A, LRX-25A & LRX-42A.
Operation Total [W]
Measure 3.7
Optional Pointer 0.9
Standby 0.2
1
1Document number
OS43418IE
Document name
Interface Control Document
Version
2.33
Page nr.
8 / 17
3 Serial communication protocol
This chapter describes the main command frames of laser range finder. Notice that all
commands described in earlier ICD document versions are still supported.
Default baud rate is 115200 bps (no parity, 8 data bits, 1 stop bit). Default electrical
interface is RS-422. RS-232 and UART are options. Serial transfer speed can be changed
by the user.
After about 50 ms from the power on the device sends a string “LRX x.x.x” where “x.x.x”
is the firmware version (e.g. 1.5.3). After the string the device is ready to take commands.